The compressor is the power part of the bullet ice machine, and the entire ice making process cannot be carried out without the compressor working.
But also because the compressor provides power, it is more susceptible to the influence of voltage and current, resulting in some ice making failures, such as the intermittent operation of the compressor.
What should I do if the compressor of the bullet ice machine works intermittently?
Starting from the cause of the failure, let’s talk about how to deal with the intermittent operation of the compressor:
1. The voltage is too low, check the overload current and power supply voltage in time.
2. The contact point is not in good contact, check the contact point and deal with it.
3. The system turns on the high voltage protection.
4. The compressor starter is faulty, check the compressor circuit to see if the starter wire is loose.
5. The condenser is too dirty, clean the filter and condenser.
6. There is non-condensable gas in the system, just re-evacuate and add fluorine.
7. The air circulation is blocked to ensure the air circulation around the machine.