What Should I Do If The Snowflake Ice Machine Only Produces Water But Does Not Make Ice?
Leave a message
What should I do if the snowflake ice machine only produces water but does not make ice?
The snowflake ice machine suitable for laboratory use can produce snowflakes and crushed ice in 15 minutes, which has the advantages of fast cooling speed and large contact surface with test tubes. But the premise of using ice is that it can produce ice. What should I do if I find that the Snowflake ice machine only produces water but does not produce ice during use?
From user feedback, it is found that there are three kinds of performances that the Snowflake ice machine does not make ice when it is out of water:
1. The compressor is working normally but not cooling
This is an "icing" problem, and ice cannot be made without refrigeration.
Therefore, you should check the refrigerant of the snowflake ice machine to see if the amount of refrigerant is insufficient, and increase the refrigerant according to the specific situation.
2. The compressor is normal, the water pump is normal, there is refrigeration but no ice
If the compressor + water pump are working normally, and the refrigeration is also normal, and you can see that the ice cubes are getting thicker, but you cannot enter the deicing process, then check the water temperature probe to see if the system cannot sense the water temperature due to a probe failure, causing errors. sentenced.
The cause of this situation may also be the fault of the controller, and the circuit needs to be repaired. You can contact the manufacturer for help.
3. After the compressor and water pump are stopped, the deicing program cannot be entered
This is also a "de-icing failure". All ice-making procedures are normal, and the water pump and compressor work normally but cannot produce ice.
Focus on checking the two-way solenoid valve to see if the solenoid valve or the outer coil needs to be replaced.