What Is The Reason Why The Snowflake Ice Machine Keeps Draining Water During Operation?
Leave a message
What is the reason why the snowflake ice machine keeps draining water during operation?
Sufficient snowflake crushed ice supply is premised on the operation of the ice machine.
But not all snowflake ice machines in operation can make ice efficiently!
For example, if the snowflake ice machine keeps draining water during the ice process, the ice making efficiency cannot be guaranteed, and even ice cannot be made!
What is the reason for this?
Why does the snowflake ice machine keep draining water during the working process?
The root cause of drainage is "ice blockage". The causes of ice blockage are as follows:
1. The evaporator is damaged
If the snowflake ice machine with damaged evaporator is turned on for a long time, the water molecules in the freezer will enter the compressor together with the water vapor in the air, and there will be a negative pressure after turning on the machine. Ice block".
2. During the pressurized leak test, the water vapor in the air is compressed into water, which is injected into the pipe to form an "ice block".
3. The process tube of the snowflake ice machine was not sealed after opening, and no attention was paid to inspection and maintenance, resulting in long-term shelving of the tube to generate frost. Coupled with occasional startup, air moisture entered from the unsealed tube opening, resulting in "ice blockage".
4. The drying filter is used for too long, the equipment is aging, and the function of drying and absorbing water disappears.
In addition, there is also a phenomenon of dirty blockage, which is caused by the long-term storage of the compressor and the fact that it has not been dried or cleaned when it is put into use.