Common faults of ice machines and their solutions
Leave a message
Compressor works intermittently:
1. The voltage is too low. Check power supply.
2. The contact point is burnt and the contact is not good.
3. System pressure protection.
4. The starter of the compressor is faulty.
5. The condenser is too dirty, high pressure protection.
Reduced ice production
1. The capillary or expansion valve is blocked.
2. The water content in the system is too high and there is a slight ice blockage.
3. The condensing system of the ice machine is blocked.
3. The condensing system of the ice machine is blocked.
4. Insufficient refrigerant or leakage.
5. The evaporator is too dirty.
Wet ice ice flakes are not hard
1. The ambient temperature is too high, especially in summer. 2. The repaired machine has more refrigerant.
3. The water supply of the water tray of the ice machine is too large.
4. The power of the compressor is insufficient.
1. There is not enough water in the water tray or there is no water. .
2. The reducer is faulty or it is the geared motor.
The machine runs but no ice comes out
3. Ice blockage due to system failure. Dirty, etc.
4. The ice maker is leaking snow, and the pressure is not enough
5. The ice cubes are not thick enough
1. The amount of water supplied to the water pan by the water inlet valve is too large.
2. The connecting water pipe is damaged.
The ice machine is leaking
3. The pipe clamp is faulty.
4. The water level float valve is faulty.
1. The fan of the ice machine is faulty.
2. The reducer is faulty.
too much noise
3. The compressor is noisy.
Water shortage alarm
1. The filter screen of the water supply connector is blocked.
2. The water supply pipe is blocked.
3. The water inlet valve is blocked.
4. The drain valve is leaking.