Common Faults Of Industrial Flake Ice Machines
Leave a message
Common faults of industrial flake ice machines:
1. The evaporator of the flake ice machine and the offset of the blade of the flake ice machine
We all know that the distance between the ice blade of the flake ice machine and the ice bucket of the evaporator is about 15 wires (0.15 mm), the gap is very close, the ice blade is slightly misaligned, resulting in uneven ice cutting or the ice blade is stuck, and the ice bucket will appear Internal noise.
Solution: Contact the after-sales service of the flake ice machine and adjust the skates. (Requires professional maintenance)
2. Salt water concentration is too low or too high
Flake ice machine The ice machine needs to add salt during the working process. If the proportion of salt water is not suitable, the freezing hardness of the ice bucket of the flake ice machine will be high. At this time, the ice knife is not easy to cut off the ice attached to the inner wall of the ice bucket, or the cutting is not clean. , there will be abnormal noise.
Solution: Please follow the instruction of the brine pump in the instruction book to stop replenishing brine. The brine pipeline of the flake ice machine is blocked. Treatment method: check the ice cleaning pipeline to ensure that the brine replenishment is normal.
3. There is air in the brine pipe in the flake ice machine
Solution: completely discharge the air to ensure that the brine enters and exits the pipe normally,
4. The brine pump of the flake ice machine is damaged
Contact the manufacturer to replace the brine pump with a new one