The snowflake ice machine shows full of ice but doesn't work why?
Leave a message
The snowflake ice machine shows full of ice but doesn't work why?
The indicator light of the snowflake ice machine shows the various states of the machine. Different states correspond to different lights. For example, when the machine is turned on, such as making ice, there will also be corresponding prompt lights when the ice making is full, and then enter the deicing process. But what if the ice machine shows that the ice is full but does not enter the next working procedure? Why is this?
Analysis of the reasons why the snowflake ice machine shows that the ice is full but does not work:
1. There is a problem with the ice full sensor
Find the full ice sensor, disconnect the line and measure the resistance with a multimeter. When the ice removal slider is open, the resistance is infinite; when the ice removal slider is closed, the resistance is zero, indicating that the ice full sensor is normal. Otherwise, it is abnormal.
It can also be measured with a temperature sensor or a photoelectric switch.
2. There is a problem with the circuit control board
The snowflake ice machine shows that the ice is full but does not work. In addition to the ice full sensor, there is a problem with the circuit control board, and there is an abnormal internal program, which can be solved by replacing the control board.
The snowflake ice machine shows that the ice is full but does not work because of the above two reasons, just discharge them one by one and deal with them. If you can't solve it yourself, you can contact the manufacturer for help.