Solutions to several common faults of snowflake ice machine

Solutions to several common faults of snowflake ice machine

Snowflake-shaped ice is widely used in hospitals, schools, laboratories, scientific research institutes and other occasions, as well as food preservation in supermarkets, fishing refrigeration, medical applications, chemicals, food processing and other industries, with a wide range of applications. The ice made by the snowflake ice machine is amorphous fine particles, relatively humid, the water content is generally between 15% and 25%, the temperature is slightly lower than zero, the plasticity is good, it is easy to take and accumulate, and can penetrate Narrow gap, fast cooling action.
Common fault solutions for snowflake ice machines:

1. Problem: The compressor keeps working to cool down, and the water pump also keeps working to pump water. The ice cubes keep getting thicker, but the dehydration program can't lose the ice.

Solution: Use a multimeter to measure the resistance of the water temperature probe (when the water temperature in the water tank is close to 0°C, unplug the three-core wire in the control box and test the resistance of the two wires on both sides), if the resistance is lower than If it is above 27K, it is judged that the controller is broken and should be replaced. If the resistance is lower than 27K, then any one of the two wires needs to be disconnected, and the resistance can be adjusted to 27K to 28K by connecting resistors in series. between.

2. Problem: The compressor works but does not make ice.

Solution: After leak detection, repair the leak and add refrigerant or replace the solenoid valve.

3. Problem: The water shortage light is on but the machine does not automatically enter water.

Solution: Check the water inlet of the pipeline, if there is no water, open the waterway and restart the machine. If the water inlet solenoid valve is faulty, replace it.