Precautions for snowflake ice machine
Leave a message
Precautions for snowflake ice machine:
1. When the compressor stops for any reason (lack of water, excessive ice, power outage, etc.), it must not be started continuously, but should be restarted every 5 minutes to avoid damage to the compressor!
2. Regularly check the water inlet and outlet pipe joints to deal with a small amount of residual water that may leak!
3. When the ice making and crushing ice is not in use, the remaining water in the inner tank should be drained, dry the inner tank of the storage refrigerator with a clean cloth, unscrew the drain joint cover at the back of the box to drain the remaining water in the water box, and then tighten it Drain connector cover!
4. When the ambient temperature drops below 0°C, there is a possibility of freezing. Drainage must be carried out to drain the water, otherwise the water inlet pipe may rupture!
5. Please unplug the power plug when cleaning and checking the ice machine and when it is not in use for more than a week.
6. The drainage pipe should be checked 1-2 times a year to prevent blockage.
Snowflake ice machine ice operation process
(1) Before starting the machine, check whether the automatic water supply device is normal and whether the water storage in the water tank is reasonable (the water level has been adjusted to the right level when the machine leaves the factory, and the user does not need to adjust it).
(2) Plug in the power supply, the ice machine starts to work, first the water pump starts to run (the water pump has a short-term air exhaust process), and after about 2 minutes, the compressor starts to start, and the machine enters the ice making state.
(3) When the thickness of the ice cube reaches the set thickness, the ice plate probe starts to start, the solenoid valve starts to work, the water pump stops working, the hot air enters the evaporator, and the ice cube falls in about 1.5 minutes. As the ice cubes fall, flip the ice flap over and open the reed switch. When the magnetic reed switch is closed again, the machine enters into another ice making process.
(4) The snowflake ice machine compressor does not stop during the entire ice making and deicing process.
(5) When the ice storage bucket is full of ice and the magnetic reed switch cannot be closed automatically, the machine will stop working automatically. When enough ice cubes are removed and the magnetic reed switch is closed again, the machine will start up after a delay of 3 minutes and re-enter the system. ice process.