Flake ice machine system failure and overload protection, how to deal with it?
Leave a message
Flake ice machine system failure and overload protection, how to deal with it?
The common faults and overload protection of the flake ice machine system are due to the accumulation of dust in the condenser, which leads to poor heat dissipation of the condenser and causes system failure. You only need to clean the condenser, reset the condenser fan overload protection button, cut off the power and turn it on again, and restart the flake ice machine to resume use.
Flake ice machine phase failure, wrong phase, high pressure, low voltage may cause system failure, how to deal with the system failure of flake ice machine? Find out the cause of the system failure first.
1. Phase failure: Check whether the power supply of the machine is out of phase, and whether the wiring is loose, and reinforce the wiring in time.
2. Wrong phase: The phase sequence is reversed, just swap any two of the three live wires.
3. Flake ice machine system failure caused by high pressure.
⑴. Check whether the condenser is blocked by sundries. Treatment method: Clean the condenser (it should be cleaned once a month).
⑵. Check whether the refrigerant charge is too much. Treatment method: release excess refrigerant.
⑶. Check whether the high pressure controller is damaged. Replace pressure controller.
4. Flake ice machine system failure caused by low voltage failure.
1. Check whether the refrigeration system is blocked.
2. Check whether the refrigerant in the refrigeration system is missing. Solution: add the same type of refrigerant.
3. Check whether the solenoid valve is damaged.
4. Whether the low pressure controller is damaged.
5. Check whether the water supply pump of the system is supplying water normally.